How to deal with the problem of ceiling fan light

With the continuous pursuit of people's quality of life, people pay attention to the practical function of home appliances, but also pay attention to its decoration and the overall collocation of home appliances. Ceiling fan light can be used for both lighting and fan. It is beautiful, fashionable and space saving. It is a popular choice for consumers who pursue high-quality life.

Fan4


Ceiling fan with light is more and more popular with the public, and it has become a fashionable and healthy trend of home decoration. However, it is inevitable that fan lamp products will be "sick" and "accident" if they are "old" or the owner does not take care of them~
The following Fengfan lighting provides you with professional guidance on general fan lamp problems and solutions:

. the fan works normally but the light is not on

1. Replace the bulb and test whether it is burnt out( Invisible fan light (please check whether the LED light source turns black)
2. Check whether the bullet piece of the lamp cap is in poor contact, and use a slotted screwdriver to move it (confirm that the power supply is off before this operation). If the LED light source of the invisible fan lamp turns black, a piece of solder or iron wire can be used to directly connect the positive and negative poles. If the light is on, it means that the LED light source is burnt out. If it is not on, it may be a driving problem.
3. For the fan lamp with remote control, after removing the above problems, remove the receiver (confirm that the power is off before operation), connect the brown black wire to the power live wire and the blue wire to the power zero wire, and then turn on the power test. If the fan and lamp are normal, it is the receiver fault, and replace it with a good set of receiver.
4. For the fan without remote control group or the fan whose fan turn light is not on after removing the receiver, after eliminating the above 123 points, check whether the 9p terminal or male and female terminals are in poor contact. If it is loose, return it.
5. If none of the above problems can be solved, it may be returned to the factory for maintenance (if the motor circuit fails, the original packaging shall be used as far as possible to protect the motor).

Esc 413 White Wifi 2

2. The fan doesn't work when the light is on

(confirm that the power supply is off before testing)
1. Check whether the motor wiring is correct. If there is wall control (lamp fan sub control), check whether the lamp fan switch is connected correctly.
2. Check whether the 9p terminal in the switch box is loose or not in place. If so, it can be classified as.
3. For ceiling fan lamp equipped with remote control group, after removing the receiver, connect the brown black wire of the motor with the live wire of the power supply and the blue wire with the zero wire of the power supply, and then turn on the power supply. If it is normal, it is the receiver failure, and a good set of receiver can be replaced.
4. After eliminating the above possibility, if the fault still exists, it is very likely that the fuse in the motor is burnt out, and it should be returned to the factory for maintenance (when returning to the factory, try to use the original packaging to protect the motor).

Esc 410a White Wifi 2

3. Lamp fan shaking

1. Check the installation environment. The ceiling should be cement ceiling or wooden ceiling with load bearing ≥ 25kg and thickness ≥ 10cm; Gypsum ceiling and wooden ceiling with load less than 25kg are not allowed to install fan lamp directly, but need to be reinforced by hanger.
2. Check whether the hanger is installed correctly and stably.
3. Check whether the combination of the hanging ball and the hanger is stable, and the groove of the hanging ball should be correctly placed with the hanger. Turn the main fan. If it can't turn, the clamping is successful; If it can be rotated and turned to the "click" sound, the clamping is successful.
4. Check whether the joint screw at the place where the suspender is connected to the main engine is locked. There are two screws here, both of which need to be locked.
5. Check whether the blade carrier and motor are locked, and whether the blade carrier and blade are locked.
6. If the above reasons are eliminated and the problem can not be solved, it is necessary to check whether the blade carrier is deformed due to impact during installation.